Ozone Test - NV200

Authors

Mark Reardon

Facility

UL Environment

Objective

To determine the peak ozone location and measure ozone concentration.

Methodology

Ozone testing was conducted in accordance to the Standard UL 867 Section 41.

Summary of Results

PASS - Steady-state conditions were reached within 24 hours with maximum ozone concentration measured of 0.037 ppm by volume.

The maximum allowable ozone concentration is 0.050 ppm.